[LinuxCNC/linuxcnc Issue#263] ERROR: emcStatus->motion.traj.queue during probing

未分类 bolang 4个月前 (10-15) 25次浏览

Issue #263 | 状态: 进行中 | 作者: Cromaglious | 创建时间: 2017-04-19


Getting an error during probing using smartprobe.ngc and a flat file using (PROBEFILE…

I get further the slower I go

Error message is

Queue is not empty after probing
is the actual error
emc/task/emctask.cc 397: interp_error: Queue is not empty after probing

LOG(G1 X21.000000 Y2.300000 Z-5.156492) was last output before error
add something so you know how far through it was
Y 24th loop and X at 240*22+210

using F360 for smartprobe and F240 for flat file.

Motherboard ITX atom1.6Ghz quadcore 2GB RAM
Linuxcnc 2.8.0-Pre1-2905
Linux Kernel 4.9.13 AMD64 PreemptRT
Debian 8.7 Jesse 64bit

Parallel port BOB
JMC-motor.com iHSS57-36-20 Integrated Closed Loop Stepper
Max Jog 6500mm/m 200steps per mm
stepgen at 20Khz
SmartProbe.ngc
(Configuration section)
G21 (Metric)
F360 (probe speed)

#=0 (X start)
#=0.1 (X increment)
#=240 (X count)

#=0 (Y start)
#=0.1 (Y increment)
#=240 (Y count)

#=0 (Z safety)
#=-15 (Z probe)
(End configuration section)


评论 (1)

#1 – grandixximo 于 2019-02-22

I can confirm this.
I have my own custom probing code too, and sometimes i get this error too, it’s weird because it may happen once, and then never happen again, even running the same exact code, really weird and hard to debug


原始Issue: https://github.com/LinuxCNC/linuxcnc/issues/263

喜欢 (0)