[Grbl_Esp32 Issue#492] GRBL not resetting on [CTRL-X]

未分类 bolang 4个月前 (10-14) 41次浏览

Issue #492 | 状态: 已关闭 | 作者: atlaste | 创建时间: 2020-07-21

标签: bug


Please answer the following questions.

1.2a/20200613

Is the problem repeatable?

Yes. If you use Candle (https://github.com/Denvi/Candle) you can reproduce this easily:

1. Hit a limit switch
2. Click ‘reset’ button in the ‘control’ section (top-right screen)
3. Click ‘unlock’ button in the ‘control’ section (top-right screen)

Resetting using a hardware switch works fine.


评论 (4)

#1 – JensHauser 于 2020-07-23

I do have the same issue after a hard limit is touched. Clicking on reset button releases the stepper motor current but that´s it


#2 – JensHauser 于 2020-07-25

Reset works with recent fix, alarm stays (hard limit still reached) until homed again. So expected behaviour.

One thing I realized

– The hard limit is touched
– Alarm pops up
– If I click e.g. on Home X or Y or Z, nothing happens (as expected)
– Reseting the user interface induces that these old orders are executed immediately

Idea: better flush the order queue with hitting reset button


#3 – bdring 于 2020-07-25

@JensHauser

I agree, that is the preferred behavior.


#4 – bdring 于 2020-07-26

Fixed thanks @MitchBradley !